SI-411-SS: Research-Grade SDI-12 Digital Output Standard Field of View Infrared Radiometer Sensor

$789.00

The SI-411 has an SDI-12 digital outputand high-quality cable terminating in pre-tinned pigtail leads for easy connection to dataloggers and controllers. The sensor has a 22° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration.

FOR MORE PRODUCT INFORMATION, CHECK OUT THESE LINKS

ProductManual

Specification Sheet

Technical Drawing

MORE INFORMATION ON APOGEE INFRARED RADIOMETERS >>click here

Full Description
Where to Buy

The SI-411 has an SDI-12 digital outputand high-quality cable terminating in pre-tinned pigtail leads for easy connection to dataloggers and controllers. The sensor has a 22° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.Sensor includes IP68 marine-grade stainless-steel cable connector 30 cm from head to simplify sensor removal and replacement for maintenance and recalibration.

FOR MORE PRODUCT INFORMATION, CHECK OUT THESE LINKS

ProductManual

Specification Sheet

Technical Drawing

MORE INFORMATION ON APOGEE INFRARED RADIOMETERS >>click here

Current Stock:
Input Voltage Requirement 4.5 to 24 V DC 电流消耗 1.5 mA (quiescent), 2.0 mA (active) Calibration Uncertainty (-30 to 65 C) 0.2 C, when target and detector temperature are within 20 C Calibration Uncertainty (-40 to 80 C) 0.5 C, when target and detector temperature are different by more than 20 C Measurement Repeatability Less than 0.05 C Stability (Long-term Drift) Less than 2 % change in slope per year when germanium filter is maintained in a clean condition Response Time 0.6 s, time for detector signal to reach 95 % following a step change, fastest data transmission rate for SDI-12 circuitry is 1 s Field of View 22° half-angle Spectral Range 8 to 14 µm; atmospheric window Operating Environment -50 to 80 C; 0 to 100 % relative humidity (non-condensing) Dimensions 23 mm diameter, 60 mm length Mass 190 g (with 5 m of lead wire) Cable 5 m of four conductor, shielded, twisted-pair wire with TPR jacket (high water resistance, high UV stability, flexibility in cold conditions), aditional cable available Warranty 4 years against defects in materials and workmanship